  1.     SECTION 10291
  2.  
  3.     ARCHITECTURAL BIRD CONTROL
  4. NOTE ** Nixalite(R) of America Inc.; stainless steel needle strips for bird control.
  5. NOTE ** 
  6. NOTE ** This section is based on products manufactured and distributed by Nixalite of America Inc., located at the following address:
  7. NOTE **    1025 16th Avenue, P.O. Box 727
  8. NOTE **    East Moline, IL  61244
  9. NOTE **    Tel:  309-755-8771 or 800-624-1189
  10. NOTE **    Fax:  309-755-0077 or 800-624-1196
  11. NOTE **    e-mail:  nixalite@qconline
  12. NOTE **    website:  www.nixalite.com
  13. NOTE ** Stainless steel needle strips are a simple, direct, and humane solution to bird control problems.  Easy to install, they are long lasting and virtually maintenance free.
  14. NOTE ** 
  15. NOTE ** SECTION 10291 - ARCHITECTURAL BIRD CONTROL; Copyright 1997, The Architect's Catalog, Inc.
  16.  
  17. PART 1    GENERAL
  18.  
  19. 1.1    SECTION INCLUDES
  20.  
  21.     A.    Stainless steel needle strips for bird control, complete with mounting clips and hardware.
  22.  
  23. 1.2    SUBMITTALS
  24.  
  25.     A.    Submit under provisions of Section 01300.
  26.  
  27.     B.    Product Data:  Manufacturer's descriptive product information, including installation instructions.
  28. NOTE ** Delete the following paragraph if color matching to the installation surface is not required.  Colored powder coating, Colorcoat(tm), is an option to stainless steel.
  29.  
  30.     C.    Sample for Color Matching:  A piece of the finished installation surface or a paint chip matching the surface color, not less than 2 inches (50 mm) square.
  31.  
  32.     D.    Verification Samples:  Actual strips of specified models, not less than 6 inches (150 mm) long.
  33.  
  34. 1.3    QUALITY ASSURANCE
  35.  
  36.     A.    Installers:  Completely familiar with installation of products similar to those required for this project.
  37.  
  38. 1.4    DELIVERY, STORAGE, AND HANDLING
  39.  
  40.     A.    Store and handle materials to avoid damage to products and injury to installers.
  41.  
  42. PART 2    PRODUCTS
  43.  
  44. 2.1    MANUFACTURERS
  45.  
  46.     A.    Acceptable Manufacturer:  Nixalite of America Inc.; 1025 16th Avenue, P.O. Box 727; East Moline, IL  61244.  ASD.  Tel: (309) 755-8771 or (800) 624-1189.  Fax: (309) 755-0077 or (800) 624-1196. E-mail: nixalite@qconline.com. Website:  www.nixalite.com
  47.  
  48.     B.    Requests for substitutions will be considered in accordance with provisions of Section 01600.
  49. NOTE ** Delete paragraph above or below;  coordinate with Division 1 requirements.
  50.  
  51.     C.    Substitutions:  Not permitted.
  52.  
  53. 2.2    BIRD CONTROL STRIPS
  54.  
  55.     A.    Strips:  Provide architectural bird control in the form of flexible needle strips made of Type 316 stainless steel, and as follows:
  56. NOTE ** Delete all but one of the following three paragraphs describing Nixalite models.  Where more than one type is required, indicate models on drawings.
  57. NOTE ** Model S is used for small birds, swallows, pigeons, and seagulls.
  58. NOTE ** Model L is used for pigeons and seagulls.
  59. NOTE ** Model N is used for pigeons, mud swallows, vultures, and other large birds.
  60.         1.    Nixalite Model S, 4 inches (102 mm) wide by 3-3/4 inches (95 mm) high, 120 needles per 12 inches (305 mm).
  61.         2.    Nixalite Model L, 4 inches (102 mm) wide by 3-3/4 inches (95 mm) high, 120 needles per 12 inches (305 mm).
  62.         3.    Nixalite Model N, 4 inches (102 mm) wide by 3-3/4 inches (95 mm) high, 120 needles per 12 inches (305 mm).
  63. NOTE ** The following two paragraphs cover special applications; delete if not required.
  64. NOTE ** Model H is a half-row model used for ledges less than 2 inches (51 mm) in depth and in conjunction with Models S, L, and N to achieve proper spacing.
  65. NOTE ** Model W is a wall-mounted type for vertical and sloped surfaces.
  66.         4.    Narrow Ledges and Where Indicated:  Nixalite Model H, 2 inches (51 mm) wide by 3-3/4 inches (95 mm) high, 60 needles per 12 inches (305 mm).
  67.         5.    Wall Mounting:  Nixalite Model W, 3 inches (76 mm) wide by 5-1/2 inches (140 mm) high, 120 needles per 12 inches (305 mm).
  68. NOTE ** Delete one of the following two paragraphs.
  69.         6.    Finish:  Natural stainless steel finish.
  70.         7.    Finish:  Manufacturer's Colorcoat(tm) powder coat finish.
  71. NOTE ** If stainless steel finish was specified above delete the following color option.  The manufacturer will match a sample of the installation surface color as closely as possible.  If this option is used, be sure to include the submission of the color sample in PART 1 under Submittals.
  72.         8.    Color:  Custom color to match installation surface.
  73.  
  74.     B.    Mounting System:  Stainless steel mounting clips and hardware as recommended by manufacturer.
  75.  
  76. PART 3    EXECUTION
  77.  
  78. 3.1    EXAMINATION
  79.  
  80.     A.    Verify that installation surfaces are ready to receive architectural bird control.  Do not proceed until unsatisfactory conditions have been corrected. 
  81.  
  82. 3.2    PREPARATION
  83.  
  84.     A.    Clean installation surfaces thoroughly.  Remove bird droppings and related bird refuse.  Remove overhanging foliage.
  85.  
  86. 3.3    INSTALLATION
  87.  
  88.     A.    Install architectural bird control in accordance with manufacturer's printed instructions.
  89.  
  90.     B.    Cover entire depth of surfaces indicated, cutting strips where necessary to fit strips to the installation surface properly.  Make strips follow curves and contours closely.
  91.  
  92.     C.    Install at spacings specified in manufacturer's instructions, for uniform appearance and without end-to-end gaps.
  93.  
  94.     D.    Inspect finished installation and make adjustments as necessary.
  95.  
  96. 3.4    CLEANING
  97.  
  98.     A.    Remove debris and waste materials from project site.
  99.  
  100.     END OF SECTION